DOUT21.STATEU to DOUT32.STATEU
Description
DOUTx.STATEU sets the state of the digital output node as follows:
0 = deactivated
1 = activated
DOUTx.STATEU is used when DOUTx.MODE = 0 (user mode).
General Information
|
Type |
R/W Parameter |
|
Units |
N/A |
|
Range |
0 to 1 |
|
Default Value |
0 |
|
Data Type |
Integer |
|
Start Version |
M_01-01-01-000 |
Variants Supported
Supported by any AKD with extended IO.
|
Fieldbus |
Index/Subindex |
Is 64 bit? | Attributes | Signed? | |
|---|---|---|---|---|---|
| Modbus | 1472 | DOUT21.STATEU | No | 8 bit | No |
| 1482 | DOUT22.STATEU | ||||
| 1492 | DOUT23.STATEU | ||||
| 1502 | DOUT24.STATEU | ||||
| 1512 | DOUT25.STATEU | ||||
| 1522 | DOUT26.STATEU | ||||
| 1532 | DOUT27.STATEU | ||||
| 1542 | DOUT28.STATEU | ||||
| 1552 | DOUT29.STATEU | ||||
| 1562 | DOUT30.STATEU | ||||
Related Topics